TSFM500-DC Digital Controllers Series DC User’s Guide

Página 2

TSFM 500 DC 8 32-1101 REV 2 710 5.5 CW and CCW Travel Limits (CW L and CCW L) Applies to TSTM / TSTMH only This setting corresponds t

Página 3 - 3.1 Mounting

TSFM 500 DC 9 32-1101 REV 2 710 Default setting: OFF Available settings: ±1V, ±2V, ±4V, OFF 5.7 Overload Settings (C OVERLOAD and T O

Página 4

TSFM 500 DC 10 32-1101 REV 2 710 5.9 Baud Rate (BAUD RATE) This setting corresponds to the baud rate setting of the computer program

Página 5 - 4 CONTROLS LAYOUT

TSFM 500 DC 11 32-1101 REV 2 710 5.11 Units of Speed (UNITS) Default setting: in/min or RPM Available settings: in/min, mm/min or RPM,

Página 6 - 5 TEST PARAMETER SETUP

TSFM 500 DC 12 32-1101 REV 2 710 5.13 Default Settings (DEFAULT?) This setting provides a quick return to factory settings, as follows:

Página 7

TSFM 500 DC 13 32-1101 REV 2 710 6 OPERATING MODES 6.1 Mode Overview Series DC controllers can be operated in three modes: 1. Basic

Página 8 - 5.1 Speed

TSFM 500 DC 14 32-1101 REV 2 710 6.2 Menu Navigation At power-up, the display will show the operation screen for whichever mode was used

Página 9 - 5.4 Dwell Time

TSFM 500 DC 15 32-1101 REV 2 710 Holding down the button for more than 0.5 seconds will enter Momentary mode, at which time an audible ind

Página 10

TSFM 500 DC 16 32-1101 REV 2 710 6.4 Cycling Mode This mode cycles the test stand between limit switches, load set points, or travel dist

Página 11 - 5.8 Control Source (CONTROL)

TSFM 500 DC 17 32-1101 REV 2 710 Once the sequence has been completed, the screen will revert to the number of cycles programmed originall

Página 12 - 5.9 Baud Rate (BAUD RATE)

TSFM 500 DC ii 32-1101 REV 2 0710 Table of Contents 1 LIST OF INCLUDED ITEMS...

Página 13 - 5.11 Units of Speed (UNITS)

TSFM 500 DC 18 32-1101 REV 2 710 The 09-1143 cable is needed to communicate between a Mark-10 gauge and the controller. The 09-1056 seria

Página 14 - 5.14 Password (NEW PWORD)

TSFM 500 DC 19 32-1101 REV 2 710 9 DIMENSIONS in [mm] 10 WARRANTY Limited Warranty on Products Any Cooper Instruments product which,

Página 15 - 6 OPERATING MODES

TSFM 500 DC 20 32-1101 REV 2 710 * Technical description of the defect: In order to properly repair a product, it is absolutely necessary

Página 16 - 6.3 Basic Mode

TSFM 500 DC 1 32-1101 REV 2 710 Thank you for purchasing a Mark-10 Series DC digital test stand controller, designed for use with Mark-10

Página 17 - 6.3.3 Overload Protection

TSFM 500 DC 2 32-1101 REV 2 710 In general, the controller can be mounted at any angle, although extra care should be taken during insta

Página 18 - 6.4 Cycling Mode

TSFM 500 DC 3 32-1101 REV 2 710 Applicable for TSTM / TSTMH test stands only Plug one end of the RJ11 cable into this connector, and the o

Página 19 - 6.5 PC Mode

TSFM 500 DC 4 32-1101 REV 2 710 5 TEST PARAMETER SETUP This section provides configuration instructions for each test parameter. The init

Página 20 - 8 SPECIFICATIONS

TSFM 500 DC 5 32-1101 REV 2 710 The following is a flow chart for the menu structure:

Página 21 - 10 WARRANTY

TSFM 500 DC 6 32-1101 REV 2 710 5.1 Speed Independent speeds can be set for both directions of movement. The parameters are labeled as fo

Página 22

TSFM 500 DC 7 32-1101 REV 2 710 5.3 Cycling (CYCLES) This setting allows the user to configure the number of cycles through which the t